BarChip: synthetic fibers for fiber-reinforced concrete

BarChip: Structural Synthetic Fibres for Fibre-Reinforced Concrete

BarChip fibres are structural synthetic fibres made of high tenacity polypropylene (PP-HT), designed to reinforce fibre-reinforced concrete (FRC — Fibre Reinforced Concrete). They partially or fully replace welded wire mesh in industrial floors, shotcrete, and precast products, reducing cracking and improving post-cracking ductility. Compliant with standard EN 14889-2.

Structural synthetic fibres

Technical comparison: BarChip 48 vs BarChip 54 vs BarChip MQ58

Parameter BarChip 48 BarChip 54 BarChip MQ58
Length 48 mm 54 mm 58 mm
Material HD polypropylene HD polypropylene Embossed HD polypropylene
Tensile strength >640 MPa >640 MPa >640 MPa
Modulus of elasticity >10 GPa >10 GPa >10 GPa
Typical dosage 3–5 kg/m³ 3–5 kg/m³ 4–6 kg/m³
Surface finish Excellent Excellent Excellent
Main application Floors, slabs Floors, slabs on piles Shotcrete, tunnels, precast products
Compliance EN 14889-2 EN 14889-2 EN 14889-2

Main applications

Application Recommended model Dosage
Industrial floors BarChip 48 / 54 3–5 kg/m³
Slabs on piles BarChip 54 / MQ58 4–6 kg/m³
Shotcrete BarChip MQ58 4–6 kg/m³
Precast products BarChip MQ58 3–5 kg/m³
Tunnels and galleries BarChip MQ58 5–8 kg/m³

Advantages over welded wire mesh

  • Three-dimensional distribution: the fibres are uniformly distributed throughout the concrete volume, eliminating the weak points typical of mesh
  • Cracking reduction: control of plastic shrinkage and load-induced cracking
  • Speed of installation: no manual mesh installation, added directly to the concrete mixer
  • Post-cracking ductility: fibre-reinforced concrete continues to carry loads even after the first crack
  • Sustainability: reduced transported weight and lower environmental impact compared to steel

FAQ — Frequently Asked Questions

Do BarChip fibres completely replace welded wire mesh?

In many applications yes, especially in industrial floors and shotcrete. The replacement depends on the structural design and must be verified by the designer according to EN 14889-2 and the fib Model Code guidelines.

What is the dosage of BarChip fibres in concrete?

3–5 kg/m³ for BarChip 48 and 54 in floors and slabs; 4–6 kg/m³ for BarChip MQ58 in shotcrete and precast products. The exact dosage depends on the residual strength class required by the design.

How are BarChip fibres added to concrete?

Directly into the concrete mixer during mixing, after adding the aggregates and before the water. Mix for at least 5 minutes to ensure uniform distribution. No special equipment is required.

What is the difference between BarChip 48, 54 and MQ58?

BarChip 48 (48 mm) and BarChip 54 (54 mm) are ideal for industrial floors and slabs; the 54 is preferred for slabs on piles where greater anchorage is required. BarChip MQ58 (58 mm, embossed surface) is the choice for shotcrete, tunnels and precast products where maximum post-cracking ductility is required.

Are BarChip fibres compliant with European standards?

Yes, they comply with standard EN 14889-2 for polymer fibres for concrete. They have CE marking and technical documentation for use in structures subject to regulations.