Chemical barrier against rising damp: P-CREAM80

Chemical DPC barrier

In short: a chemical DPC barrier creates a continuous water-repellent band at the base of the wall, preventing water from rising through the capillaries. It is suitable when stains, salt efflorescence, and crumbling plaster appear at the lower part of the walls.

The solution proposed by Pigment Al is P-CREAM80 (Achibuild Cream 80), a concentrated alkylsilane-based cream impregnating agent, certified Class A according to the CSTC/LERM method.

How does a chemical DPC barrier work?

The product is injected into a series of holes drilled at the base of the wall. As it spreads through the masonry, it forms a continuous water-repellent band that obstructs the capillary rise of water and dissolved salts.

P-CREAM80 does not block the natural breathability of the substrate: moisture already present can continue to evaporate outwards, while the new supply of water from the ground is limited.

The product is suitable for masonry made of stone, brick, tuff, sandstone, and concrete. Before treatment, however, it is necessary to check the condition, absorption, and continuity of the masonry.

Technical characteristics of P-CREAM80

Property Value
Appearance Yellow-white cream
pH 6–8
Chemical base Concentrated alkylsilanes
Certification Class A according to the CSTC/LERM method
Shelf life 2 years in sealed original packaging
Storage temperature From 5 °C to 40 °C
Frost protection Store at a temperature above 5 °C

Step-by-step application method

  1. Drill holes 12 mm in diameter at the base of the wall, at a height between 5 and 15 cm.
  2. Angle the holes downwards between 5° and 15° to limit the leakage of the cream during injection.
  3. Maintain a distance of 10–12 cm between holes.
  4. Reach a depth of at least four-fifths of the wall thickness.
  5. For walls thicker than 40 cm, drill from both sides, staggering the holes by about 6 cm.
  6. Inject P-CREAM80 using a cartridge gun or low-pressure pump until the hole is filled.
  7. Seal the holes with a compatible cement mortar.
  8. Remove the damaged plaster and restore it after an adequate drying period.

Indicative hole depth

Wall thickness Hole depth Method
110 mm 100 mm Drilling from one side
220 mm 190 mm Drilling from one side
330 mm 310 mm Drilling from one side
440 mm 310 mm per side Drilling from both sides, with holes staggered by about 6 cm

Indicative dosages of P-CREAM80

Wall thickness 10 linear m 20 linear m 30 linear m 40 linear m
110 mm About 1,000 ml About 2,000 ml About 3,000 ml About 4,000 ml
220 mm About 2,000 ml About 4,000 ml About 6,000 ml About 8,000 ml
330 mm About 3,500 ml About 4,700 ml About 8,500 ml About 13,500 ml
440 mm To be determined by a test About 6,500 ml About 10,000 ml About 18,500 ml

The dosages are indicative. Before application, it is recommended to perform a test depending on the thickness, porosity, and absorption capacity of the masonry.

Available formats

  • 20 kg drum: suitable for medium-sized construction sites.
  • 110 kg drum: suitable for large surfaces and professional applicators.
  • 600 ml cartridge: usable with a cartridge gun for localized treatments.

Why choose P-CREAM80?

  • Certified Class A according to the CSTC/LERM method.
  • Does not alter the natural breathability of the masonry.
  • Combats capillary rise and the formation of salt efflorescence.
  • Applied with a cartridge gun or low-pressure pump.
  • Available in cartridges and drums for treatments of different sizes.
  • The cream formulation promotes spreading through the pores of the masonry.

Frequently asked questions about chemical DPC barriers

How does a chemical DPC barrier work?

The cream is injected into holes drilled at the base of the wall and forms a continuous water-repellent band that limits the capillary rise of water.

Does a chemical DPC barrier work on already very damp walls?

P-CREAM80 can also be applied to damp masonry, but the condition of the substrate, the causes of moisture, and the method of treatment must be assessed before application.

How long does a chemical DPC barrier last?

The lifespan depends on the correct design of the treatment, the continuity of the barrier, the condition of the masonry, and the quality of the application.

Is it necessary to remove the plaster?

It is not always essential before injection, but it is advisable to remove damaged or salt-contaminated plaster to promote drying and subsequent restoration.

Can a chemical DPC barrier be applied to tuff walls?

Yes, P-CREAM80 is suitable for masonry made of tuff, stone, brick, sandstone, and concrete, after checking the absorption of the substrate.

Related products and guides

Learn more about our cement protectors, plaster protectors, and the range of resins and protectors.

For technical information and orders, write to info@pigmental.it.

Application of the P-CREAM80 chemical DPC barrier against rising dampness